Fuel basics

Btu, Joule and kWh: How Energy Units Convert

Close-up view of a row of industrial electricity meters for power monitoring and technology
Photo by Connor Scott McManus on Pexels. A general illustration, not evidence for any number.

One kilowatt-hour (kWh) equals 3.6 megajoules (MJ) and about 3,412 British thermal units (Btu). One Btu is about 1,055 joules. With those two facts you can convert almost any energy figure you meet in fuel data, because all three units measure the same thing, energy, and differ only in size and history.

The arithmetic is short. The traps are elsewhere: units that sound alike (kW and kWh), numbers that rest on different heating-value bases, and ratios such as "kg of CO2 per million Btu" that change shape when the unit changes. Below are the factors, one worked example with propane, and a checklist. Comparing fuels once the units match is the job of energy density by mass and volume and of the Comparator.

What each unit measures

Joule (J). The joule is the SI unit of energy, work and heat. The National Institute of Standards and Technology (NIST) lists it as one newton-meter, or m²·kg·s⁻² in base units. Fuel data usually uses larger multiples: mega (M) means 10⁶, so 1 MJ is one million joules, and giga (G) means 10⁹.

Kilowatt-hour (kWh). A kilowatt measures power, the rate of using energy. A kilowatt-hour is that rate sustained for one hour. The U.S. Energy Information Administration (EIA) gives an example: a 40-watt (0.04 kW) bulb running five hours uses 200 watt-hours, or 0.2 kWh. NIST gives the conversion as exactly 3.6 million joules per kWh. That also shows that one watt for one second is one joule, since 1 kWh is 1,000 W × 3,600 s.

British thermal unit (Btu). EIA defines one Btu as the heat needed to raise the temperature of one pound of water by 1°F. It is common in U.S. fuel data. NIST lists two versions: the International Table Btu at 1,055.056 J and the thermochemical Btu at 1,054.350 J, which differ by about 0.07%. This page uses the first.

The conversion table

Common energy conversions, built from NIST's exact kWh factor and the International Table Btu.
1 unit of...In joulesIn kWhIn Btu
Btu1,055.056 J0.000293 kWh1
kWh3,600,000 J (3.6 MJ)13,412
Megajoule (MJ)1,000,000 J0.2778 kWh947.8
Therm105.5 MJ29.31 kWh100,000
Million Btu (mmBtu)1,055 MJ (1.055 GJ)293.1 kWh1,000,000

EIA's own factor is 1 kWh = 3,412 Btu, which is 3.6 million joules divided by 1,055.056 and rounded. It also defines the therm as 100,000 Btu and lists a food calorie as 3.9683 Btu. The table's other values follow by multiplication and division.

Worked example: a gallon of propane in three units

The DOE Alternative Fuels Data Center (AFDC) lists propane at 91,420 Btu per gallon on a higher heating value (HHV) basis. Take 1 US gallon (3.78541 L) and convert it.

  1. Btu to joules. 91,420 Btu × 1,055.056 J per Btu = about 96,453,000 J, or 96.45 MJ.
  2. Joules to kWh. 96.45 MJ ÷ 3.6 MJ per kWh = 26.79 kWh.
  3. Cross-check. 91,420 Btu ÷ 3,412 Btu per kWh = 26.79 kWh. Both routes agree.
  4. Per liter. 96.45 MJ ÷ 3.78541 L = 25.48 MJ/L, the figure the Comparator shows for propane.

Now change the basis. AFDC lists the same propane at 84,250 Btu per gallon on a lower heating value (LHV) basis. The same steps give 88.89 MJ, or 24.69 kWh. The unit conversion is exact, but the HHV figure is about 8.5% above the LHV figure (91,420 ÷ 84,250). Conversions never fix a basis mismatch, which is the subject of higher vs lower heating value.

A checklist for any conversion:

  • Write down the unit and the basis (HHV or LHV) of the number you start with.
  • Convert to one base unit first, joules or Btu, before converting again.
  • Keep two extra digits until the last step, then round.
  • Check the result against a second route, as in step 3 above.
  • Note whether the figure is per gallon, per liter, per pound or per kilogram, and convert that part too. Gasoline gallon equivalents rely on exactly this.

Converting ratios: from kg per million Btu to g per MJ

Emission factors are ratios, so the energy unit sits in the denominator. When the energy unit gets bigger, the number per unit gets bigger too, and the conversion divides where a plain quantity would multiply. EPA publishes the CO2 factor for propane as 62.87 kg per million Btu. Since one million Btu is 1,055.056 MJ:

  • 62,870 g ÷ 1,055.056 MJ = 59.59 g of CO2 per MJ of propane heat.
  • 59.59 g/MJ × 3.6 MJ per kWh = 214.5 g per kWh of propane heat, or about 0.473 lb.

EIA gives a national average for electricity generation of 0.785 lb of CO2 per kWh, for 2024, the latest year published as of November 2026. That is 0.785 × 453.59 g = 356 g per kWh, or 98.9 g per MJ of electricity.

Those two lines do not rank propane against the grid. The propane factor is tied to fuel heat burned, and the grid factor is tied to electric energy generated. Same unit symbol, different things measured. The point here is only that a factor must be converted into matching units before any two are set side by side.

Common mistakes

  • Confusing kW and kWh. A kilowatt is a rate, and a kilowatt-hour is an amount. EIA's 40-watt bulb example shows the difference: the bulb's power is 0.04 kW, but five hours of use is 0.2 kWh.
  • Treating a kWh of electricity and a kWh of fuel heat as the same thing. The unit is identical, but converting units does not account for how energy is produced or used.
  • Mixing HHV and LHV before converting. A gallon of propane is 26.79 kWh on one basis and 24.69 kWh on the other.
  • Using one Btu for every source. NIST lists the International Table and thermochemical versions, about 0.07% apart. The gap is negligible for fuels, but a table should say which it uses.
  • Mistaking the food calorie for the small calorie. EIA lists 1 food calorie as 1,000 calories, or 3.9683 Btu.
  • Converting a ratio the wrong way. A factor per million Btu becomes a factor per MJ by dividing by 1,055.056 (62.87 kg per million Btu is 59.59 g per MJ). Multiplying instead gives a wildly wrong number.

Frequently asked questions

How many Btu are in a kWh?

About 3,412. EIA lists 1 kWh = 3,412 Btu. The exact route is NIST's 3,600,000 joules per kWh divided by 1,055.056 joules per Btu, which gives 3,412.14, rounded to 3,412. Going the other way, one Btu is about 0.000293 kWh.

How many kWh are in a gallon of propane?

About 26.8 kWh of heat on an HHV basis (91,420 Btu), or about 24.7 kWh on an LHV basis (84,250 Btu). The difference comes from whether the energy in the combustion water vapor is counted, not from the conversion. To check the arithmetic yourself, divide the Btu figure by 3,412, EIA's factor for Btu per kWh.

How do you convert megajoules to Btu?

Multiply by 947.8. One megajoule is one million joules, and one Btu is 1,055.056 joules, so 1,000,000 ÷ 1,055.056 gives 947.8. For example, 96.45 MJ is about 91,400 Btu, the propane figure above. To go the other way, from Btu to MJ, multiply by 1,055.056 and divide by one million.

What is a therm?

A therm is 100,000 Btu, according to EIA. That equals about 105.5 MJ or 29.3 kWh. NIST lists two versions, one labeled EC at 105.506 MJ and the U.S. therm at 105.480 MJ, a difference of about 0.02%, too small to matter for most fuel questions. A million Btu is ten therms.

Sources

Spotted something wrong or out of date? Tell us through the corrections page. We answer within 10 business days.