Biofuels and alternatives

Biomass and Wood as Fuel: Energy Content and Moisture

A close-up view of a neatly stacked pile of cut firewood, showcasing the textures and patterns of the wood
Photo by lil artsy on Pexels. A general illustration, not evidence for any number.

A kilogram of dry wood holds about 20.33 MJ of energy (8,740 Btu per pound) on a higher heating value (HHV) basis, using the default value in EPA's emission factor tables. Bituminous coal holds 28.99 MJ/kg on the same basis, so dry wood carries about 70% as much energy per kilogram. Wood fresh from the tree is often about half water, though, and that water changes the answer far more than most readers expect.

Biomass is a wider word than wood, and the energy numbers for it only make sense once you know how much of the weight is water. This article sets out what counts as biomass fuel, what a dry kilogram of wood holds, how moisture removes energy in two separate ways, and why logs, chips and pellets behave differently. How wood's carbon is counted is a different question, covered in carbon neutral fuel claims.

What counts as biomass fuel

The U.S. Energy Information Administration (EIA) defines biomass as renewable organic material from plants and animals. Wood and wood waste, meaning bark, sawdust, wood chips, wood scrap and paper mill residues, plus the firewood and pellets burned in homes, is one family. Crops and farm residues, the biogenic part of municipal solid waste, and manure are others. EIA says direct combustion is the most common way to release the energy, producing heat for buildings and industry or steam for electricity.

EIA's preliminary figures for 2025 put biomass at about 5% of U.S. primary energy consumption and wood and wood waste at about 2%. Industry burned about 68% of that wood, mostly mill waste used for steam and electricity, and homes used about 19%. In 2020, about 8.9% of U.S. households, roughly 11 million, used wood for energy, and about 2.2 million relied on it as their main heating fuel. EIA adds that some coal plants burn wood chips alongside coal to cut sulfur dioxide emissions. For how wood sits among home options, see home heating fuels overview, and for the supply label, renewable vs nonrenewable energy sources.

Dry wood and coal on one basis

Dry wood and bituminous coal, higher heating value (HHV) basis and combustion CO2, from EPA's 2025 emission factor tables.
PropertyWood (dry)Coal (bituminous)
Energy per mass (HHV)20.33 MJ/kg (8,740 Btu/lb)28.99 MJ/kg (12,465 Btu/lb)
Energy per short ton (HHV)17.48 million Btu24.93 million Btu
CO2 from burning, per unit of HHV energy88.91 g/MJ (93.8 kg per million Btu)88.41 g/MJ (93.28 kg per million Btu)
How EPA classes the CO2Biogenic, reported separatelyFossil

The arithmetic: 20.33 ÷ 28.99 is about 0.70. EPA's greenhouse gas reporting rule labels the 17.48 million Btu per short ton for wood explicitly as a dry-basis value, but puts no moisture label on the 24.93 for coal, so the 70% compares dry wood with coal of unstated moisture. Per unit of energy, wood's CO2 at the point of burning is within 1% of coal's. That is a combustion measure only. EPA's inventory guidance says the GHG Protocol requires CO2 from burning biomass to be reported as biogenic CO2 and tracked apart from fossil CO2, and it quotes EPA's Science Advisory Board saying that net biogenic emissions vary considerably with the feedstock. The sourced numbers for the two fuels sit in the Comparator for wood and coal. The Comparator also records lower heating values from the IPCC's 2006 inventory guidelines: 15.6 MJ/kg (6,707 Btu/lb) for wood, within a published range of 7.9 to 31.0, and 25.8 MJ/kg (11,092 Btu/lb) for bituminous coal. The IPCC table states no moisture level for its wood value, and EPA's HHV is dry basis, so the two wood numbers are not a matched pair: the gap between 20.33 and 15.6 mixes the heating-value basis with an unknown difference in moisture. Every other energy figure here is HHV. The gap between the two bases is explained in higher vs lower heating value, and coal itself in coal ranks and energy content.

Why moisture matters twice

Moisture is quoted in two ways. Penn State Extension defines wet-basis moisture as the water's mass divided by the total mass of the fuel, and dry-basis moisture as the water's mass divided by the mass of the dry part. A fuel at 50% wet basis is at 100% dry basis. The conversion is dry basis = wet basis ÷ (100% − wet basis), so 20% wet is 25% dry. Penn State also says fresh green wood is often about half water, and that the practical limit for combustion is about 60% on a wet basis.

Water costs energy in two ways. First, it displaces wood: a kilogram of wet fuel holds less wood. Second, burning it evaporates the water, and Penn State says much of the energy in wet fuel is used to heat and vaporize that water. The U.S. Geological Survey gives the heat of vaporization of water as 2,260 kilojoules per kilogram (about 970 Btu per pound).

EPA's reporting rule gives the matching adjustment: a wet-basis heating value equals the dry-basis value times (100 − M) ÷ 100, where M is the moisture percentage. The rule does not name the basis, but the formula is right only for wet-basis moisture. The example below uses that rule.

Worked example, one kilogram of green wood at 50% moisture (wet basis):

  • Dry wood present: 1 kg × (1 − 0.50) = 0.50 kg.
  • Its energy, using the dry-wood HHV: 0.50 × 20.33 = about 10.2 MJ.
  • Water to evaporate: 0.50 kg × 2.26 MJ/kg = about 1.1 MJ, roughly 11% of the 10.2 MJ.
  • Against coal: 10.2 ÷ 28.99 is about 0.35, so a kilogram of green wood holds about a third of the energy in a kilogram of coal.
One kilogram of wood as received at different moisture levels (wet basis), using dry-wood HHV. Do not subtract the last column from the fourth: HHV already assumes the vapor condenses and returns its heat, so the evaporation energy is a loss only when the water leaves as steam. A simplified estimate; real appliances differ.
Moisture, wet basisSame moisture, dry basisDry wood per kgEnergy of that wood (HHV)Energy to evaporate the water
0%0%1.00 kg20.3 MJ (8,740 Btu/lb)0
20%25%0.80 kg16.3 MJ (6,990 Btu/lb)0.45 MJ
35%54%0.65 kg13.2 MJ (5,680 Btu/lb)0.79 MJ
50%100%0.50 kg10.2 MJ (4,370 Btu/lb)1.13 MJ

A moisture figure is meaningless without its basis. A figure of 25% on a wet basis equals about 33% on a dry basis (25 ÷ 75), while 25% on a dry basis equals 20% on a wet basis (25 ÷ 125). Check the basis whenever you see a moisture target.

Logs, chips and pellets

Form changes how much fuel fits in a space. Penn State lists bulk densities, meaning the mass of loose fuel per cubic meter.

Bulk density of biomass fuel forms, from Penn State Extension.
FormBulk density
Chopped straw60 kg/m³ (3.7 lb/ft³)
Sawdust300 kg/m³ (18.7 lb/ft³)
Cordwood400 kg/m³ (25.0 lb/ft³)
Green wood chips500 kg/m³ (31.2 lb/ft³)
Wood pellets600 kg/m³ (37.5 lb/ft³)

Pellets hold ten times the mass of chopped straw in the same volume. Penn State's ash figures add another contrast: clean dry wood is 0.3% ash, bark 1.2%, switchgrass 5.2%, corn stover 5.6% and coal 12%. No sourced energy-per-volume value exists for wood in the Comparator, so these densities describe mass, not energy. Wood smoke is a separate topic, covered in air pollutants from burning fuels.

Common mistakes

  • Using the dry figure for wet wood. The 20.33 MJ/kg value is for dry wood. Green wood at 50% moisture holds only about half that per kilogram before any evaporation loss.
  • Mixing moisture bases. A 50% wet-basis fuel is a 100% dry-basis fuel. A target quoted without its basis can mean very different wood.
  • Assuming "biomass" means one fuel. EIA's wood family alone includes bark, sawdust, wood chips, wood scrap, paper mill residues, firewood and pellets, and biomass also includes crops, waste and manure.
  • Reading "renewable" as "less CO2 at the chimney." Per unit of HHV energy, EPA's factor for wood is 88.91 g/MJ against 88.41 g/MJ for bituminous coal. The renewable label is about supply and carbon accounting.
  • Comparing heating values on different bases. HHV and LHV values cannot be set side by side, and one fuel's pair can differ in moisture too: the Comparator's wood HHV (EPA, dry basis) and wood LHV (IPCC, moisture not stated) are not a matched pair.

Frequently asked questions

How much energy is in a pound of wood?

EPA's default for dry wood and wood residuals is 17.48 million Btu per short ton on an HHV basis, which is 8,740 Btu per pound (20.33 MJ/kg). Wetter wood holds less per pound because part of the weight is water. At 50% moisture, wet basis, only about 4,370 Btu per pound of wood remains before evaporation losses.

Why is seasoned firewood better than green wood?

Seasoned wood has less water, so each kilogram holds more wood and less energy goes to evaporating water. Penn State says much of the energy in wet fuel is used to heat and vaporize the water. By the table above, a kilogram at 20% moisture (wet basis) holds 0.80 kg of dry wood, against 0.50 kg at 50%.

What is the difference between wet-basis and dry-basis moisture?

Wet basis divides the water's mass by the total mass of wood plus water. Dry basis divides it by the dry wood's mass alone. Penn State's example is that 50% wet basis equals 100% dry basis. Dry-basis values can exceed 100%, while wet-basis values cannot.

Does wood give off less CO2 than coal?

Not per unit of energy at the point of burning. EPA lists 88.91 g CO2 per MJ for wood and 88.41 g per MJ for bituminous coal, both on an HHV basis. EPA reports wood's CO2 as biogenic, tracked separately from fossil CO2. Whether that carbon is offset depends on the feedstock, and sources describe it as varying considerably.

Sources